Multi Gas DGA

The world's most advance DGA solutions

hero_relay_control (2)

Transformers are the most critical assets of the power system, and there continuous monitoring is required. Single gas DGA on transformer oil can analyze much about the transformer health, but it alone can't detect all the faults, so multi-gas dissolved gas analysis is required to draw the correct image about the transformer health. EPESOL provided IEEE/IEC/ETRA/Duval complaint advanced devices can analyze the concentration of up to ten gases in the oil with near-real-time results. These low-cost, online, and offline devices continuously monitor the transformer's health and inform the customer about any malfunctioning.

Multi Trans
  • On-line DGA monitoring unit.
  • Used for a bank of 2 to 3 single phase transformers.
  • Discrete measurement of 8 fault gases plus moisture and nitrogen.
  • Load sensors, inputs, outputs, alarms and extensive communication options
Tap Trans
  • On-line Transformer and OLTC DGA monitoring unit.
  • 8-gas analyzer plus oxygen and moisture.
  • Load sensors, inputs/outputs, configurable alarms and extensive communication options.
     
Trans  Fix
  • On-line Transformer DGA monitoring unit.
  • 8-gas analyzer plus nitrogen and moisture.
  • Features load sensors, inputs/outputs, configurable alarms and exclusive local and remote communication.
Mini Trans
  • Low-cost On-line Discrete Multi-gas DGA Transformer Monitoring Unit
  • Discrete DGA device monitoring of 3 significant fault gases plus moisture.
  • Used for 3 phase transformers
  • Includes load sensor, outputs, extensive communications and configurable alarms.

Discover More

Single

Gas DGA

Transformer oil is subjected to electrical stress, and this stress can cause the oil to break down, creating gases within the transformer oil. GE single gas DGA can track the percentage

Portable  

DGA

EPESOL offers for the first time in Pakistan an on-site DGA facility through its state-of-the-art on-site DGA test-set, Transport . The second-generation Transport is a compact

Complete

Monitoring

Along with DGA and bushing failures, there are also several other failures such as the main tank accounting for 30%, Tap changer accounting for 35%, and the Cooling system accounting

Bushing

Monitoring

Bushing failure is one of the leading cause of transformer failure, accounting for 15% of the total failures. Faulty insulation is the principal cause of bushing failure. Humidity and oil