Capacitors

Blazing fast subcycle protection

hero_relay_control (2)

EPESOL provided capacitors are designed for use in shunt bank, harmonic Filter, series, SVC applications in all climatic conditions. These power capacitors are film types with very low dielectric losses and a long lifetime. The capacitors are impregnated with a biodegradable, non-PCB fluid with high insulation strength. The edges of the electrode foils are folded, enabling higher electrical stress. The ABB capacitor units have an extremely low failure rate and high reliability. Due to their enhanced reliability and efficiency, these capacitors are currently used all across the country in national as well as distribution transmission systems.

Technical data

  • Power Max.800 / 900 kvar (50 / 60 Hz)
  • Voltage 1-23 kV
  • Current Max.180 A
  • Dielectric
  • Polypropylene film
  • Impregnant Faradol 810 (non-PCB)
  • Discharge Resistor Built-in
  • Standard IEC 60871-1 (2005), IEEE Std18-2002

Operating conditions

  • Temp. range -40/+50 (other data on request)
  • Location Indoor or outdoor

Terminations

  • Bushing Porcelain, single or double bushing, grey color
  • Terminals M16 2.0
  • Clamp Nickel-coated brass, max. 2 70 mm

Capacitor container

  • Material Ferritic stainless steel
  • Surface Treatment Surface mineral blasted and painted
  • Color Munsell # 5.0 BG 7.0 / 0.4 (Standard Color, same as Ansi Gray 70)
  • Fixing Brackets One or two per side

S1

  • BIL 095 KV
  • Creepage 380 mm
  • Dimension 230 mm

S3

  • BIL 150 KV
  • Creepage 600 mm
  • Dimension 310 mm

S5

  • BIL 170 KV
  • Creepage 780 mm
  • Dimension 370 mm

Discover More

Multi Gas

DGA

 Transformers are the most critical assets of the power system, and there continuous monitoring is required. Single gas DGA on transformer oil can analyze much about the transformer

Portable

DGA

EPESOL offers for the first time in Pakistan an on-site DGA facility through its state-of-the-art on-site DGA test-set, Transport . The second-generation Transport is a compact

Complete

Monitoring

Along with DGA and bushing failures, there are also several other failures such as the main tank accounting for 30%, Tap changer accounting for 35%, and the Cooling system accounting

Bushing

Monitoring

Bushing failure is one of the leading cause of transformer failure, accounting for 15% of the total failures. Faulty insulation is the principal cause of bushing failure. Humidity and oil