Select Sidearea

Populate the sidearea with useful widgets. It’s simple to add images, categories, latest post, social media icon links, tag clouds, and more.

hello@youremail.com
+1234567890

Portable DGA

The world's most advance DGA solutions

hero_relay_control (2)

EPESOL offers for the first time in Pakistan an on-site DGA facility through its state-of-the-art on-site DGA test-set, Transport . The second-generation Transport is a compact, portable DGA system that is designed to analyze Oil samples in the field and obtain not only gas level readings but also delivers diagnostics based on standard rules. With Transport being introduced the possibility of a loss of gas or loss of sample integrity during the delay involved in transporting the sample to a lab is omitted. EPESOL renowned Field Services team has an excellent record of providing these blazing fast services bots in Pakistan and abroad.

Transport

  • Measurement of 7 fault gases plus moisture(water) from manual oil sample
  • Provides result in 30minutes of testing
  • Analysis on basis of IEEE/IEC/ETRA/Duval diagnostic tool
  • Keep record of 20000 tests in internal storage
  • Robust design with IP-67 when closed

No longer wait for months to get a piece of paper that too not reliable!

EPESOL offers for the first time in Pakistan on-site DGA facility through its state-of-the-art on-site DGA test-set, Transport X. The TRANSPORT X is a compact, portable DGA system which is designed to analyze oil samples in the field and obtain not only gas level readings but also deliver diagnostics based on standard rules. The TRANSPORT X unit has been designed to be very rugged and user friendly with an emphasis placed on easy field operation. EPESOL infamous Field Services team had an excellent record of providing these blazing fast services both in Pakistan and abroad.

Transport X


On-site analysis increases speed and decreases cost at which results can be obtained


  • Avoids time consuming process of documenting, packaging and shipping samples to a laboratory
  • DGA at a commercial lab in the US or Europe costs approximately $200 each
  • The customer can test the sample in the time it would take to package the sample and ship it.
  • The sample can be tested immediately, on-site, thus reducing the possibility of loss of gas or loss of sample integrity during the delay involved in transporting the sample to a lab
  • Requires no consumables (columns, carrier or calibration gases) and requires minimal training making the cost per test lower than for any other portable DGA product on the market
  • The definitive FAST FIRST RESPONSE TOOL, providing full DGA results in less than 30 mins. No other technique can match this time in an emergency situation.

Transport X2

 

Key Features

 

  • Measurement of 7 fault gases plus moisture(water) from manual oil sample
  • Provides result in 30minutes of testing
  • Analysis on basis of IEEE/IEC/ETRA/Duval diagnostic tool
  • Keep record of 20000 tests in internal storage
  • Robust design with IP-67 when closed.

Discover More

SIngle Gas

DGA

Transformer oil is subjected to electrical stress, and this stress can cause the oil to break down, creating gases within the transformer oil. GE single gas DGA can track the percentage

Multi Gas

DGA

 Transformers are the most critical assets of the power system, and there continuous monitoring is required. Single gas DGA on transformer oil can analyze much about the transformer

Complete

Monitoring

Along with DGA and bushing failures, there are also several other failures such as the main tank accounting for 30%, Tap changer accounting for 35%, and the Cooling system accounting

Bushing

Monitoring

Bushing failure is one of the leading cause of transformer failure, accounting for 15% of the total failures. Faulty insulation is the principal cause of bushing failure. Humidity and oil